Abstract
This work presents the electronic and mechanical design of an emerging mechanical ventilator that allows the control of variables such as Peak inspiratory pressure (PIP), Positive end-expiratory pressure (PEEP), Respiratory Frequency (FR), Inspiring Time (Ti), Inspiring pause (Pause ins), Trigger Sensitivity, Apnea in Spontaneous Mode (Apnea). For the design, previous experience in the handling of medical mechanical fans and the use of industrial-type stainless steel (316 steel) components and medical equipment was considered. This ventilator allows mandatory control, selection and monitoring of minimum parameters necessary to provide life support to patients with acute respiratory deficiency.
Keywords: ventilator, positive end-expiratory pressure (PEEP), peak inspiratory pressure (PIP), COVID-19.
References
[1]F. Gutierrez, “Ventilación mecánica”, Acta Médica Peruana, vol. 28, no. 2, Junio 2011.
[2]F. Gutiérrez, “Diagnóstico, Monitoreo y Soporte Inicial del Paciente con Insuficiencia Respiratoria Aguda”;Simposio: “Atención Inicial Del Paciente Crítico Para No Especialistas” (Parte 1). Revista Acta Médica Peruana, no. Especial, 2011.
[3]Y. Rodríguez, D. Rodriguez, A. Monsalve, K. López and A. Arévalo, “Recomendacones clínicas para la atención del paciente agudo y crítico con COVID-19”, Abril 2020. [4]Grace K, “The Ventilador: selection of mechanical ventilators.” Critical Care Clinics, Vol. 14, no. 4, Octubre 1988.
[5]J.A. Farias, I. Alía, A. Retta, F. Olazarri, A. Fernández and A. Esteban, “An evaluation of extubation failure predictors in mechanically ventilated infants and children.”, Intensive Care Med., pp. 752-757, 2002.
[6]A. Chavez, R. De la Cruz and A. Zaritsky., “Spontaneous breathing trial predicts successful extubation in infants and children.”, Pediatr Crit Care Med., pp. 324-328, 2006.
[7]C. M. Reina, “Ventilación mecánica controlada y asistida y controlada.”, Science Direct, vol. 59, pp. 82-85, 2003.
[8]P. Jouvet, C. Farges, G. Hatzakis, A. Monir, F. Lesage and L. Dupic, “Weaning children from mechanical ventilation with a computer-driven system (closed-loop protocol): a pilot study.” Pediatr Crit Care Med., pp. 425-432, 2007.
[9]F. Scopesi, M.G. Calevo, P. Rolfe, C. Arioni, C. Traggiaia and F.M. Risso, “Volume targeted ventilation (volume guarantee) in the weaning phase of premature newborn infants.”, Pediatr Pulmonol., pp. 864-870, 2007.
[10]M. Sánchez, M. Quintana, D. Palacios, V. Hortiguela, C. Schulk, J. Garcia, A. Canabal, M.J. Pérez, A. Velasco and M.A. Arrense, “Relación entre el gradiente alveolo-arterial de oxígeno y la PaO2/FiO2 introduciendo la PEEP en el modelo.”, Medicina Intensiva, vol. 36, no. 5, Junio- Julio 2012.